{"product_id":"model-122-silconert-2000","title":"Model 122 SilcoNert® 2000 Coated Stainless Steel Analyser Filter Housing","description":"\u003ch2\u003eModel 122 – SilcoNert® 2000 Coated Stainless Steel Filter Housing\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e316L stainless steel analyser filter housing with SilcoNert® 2000 treated wetted surfaces for analytical and sample conditioning applications where surface inertness and sample integrity are critical.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e316L stainless steel head, bowl and internals\u003c\/li\u003e\n\u003cli\u003eSilcoNert® 2000 treated wetted surfaces\u003c\/li\u003e\n\u003cli\u003eCoating applied by SilcoTek® Corporation, USA\u003c\/li\u003e\n\u003cli\u003e1\/4\" NPT inlet and outlet connections\u003c\/li\u003e\n\u003cli\u003e1\/4\" NPT drain connection\u003c\/li\u003e\n\u003cli\u003eMaximum working pressure: \u003cstrong\u003e340 bar\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum operating temperature: \u003cstrong\u003e200°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eInternal volume: \u003cstrong\u003e30 cc\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eViton® O-ring supplied as standard\u003c\/li\u003e\n\u003cli\u003eCompatible with Headline Filters \u003cstrong\u003e12-57 series filter elements\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for gas and liquid analyser sample systems\u003c\/li\u003e\n\u003cli\u003eManufactured by Headline Filters Limited in the UK\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Headline Filters \u003cstrong\u003eModel 122 SilcoNert® 2000\u003c\/strong\u003e combines our compact, high-pressure Model 122 stainless steel filter housing with an inert surface treatment specifically suited to demanding analytical and sample conditioning applications.\u003c\/p\u003e\n\u003cp\u003eThe housing is manufactured from \u003cstrong\u003e316L stainless steel by Headline Filters in the UK\u003c\/strong\u003e before being treated with \u003cstrong\u003eSilcoNert® 2000 by SilcoTek® Corporation in the USA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis coated version is intended for applications where maintaining the composition of the sample as it passes through the filtration stage is particularly important.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eWhy Use SilcoNert® 2000?\u003c\/h3\u003e\n\u003cp\u003eIn an analyser sample system, the filter housing forms part of the wetted sample path.\u003c\/p\u003e\n\u003cp\u003eCertain reactive compounds can interact with untreated stainless-steel surfaces. This can result in adsorption of sample components, delayed analyser response, reduced recovery and variation when measuring trace concentrations.\u003c\/p\u003e\n\u003cp\u003eSilcoNert® 2000 creates a highly inert silicon-based barrier over the treated stainless-steel surface.\u003c\/p\u003e\n\u003cp\u003eThis helps to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduce adsorption of reactive compounds onto stainless steel\u003c\/li\u003e\n\u003cli\u003ePreserve sample integrity through the filtration stage\u003c\/li\u003e\n\u003cli\u003eImprove analyser response\u003c\/li\u003e\n\u003cli\u003eReduce sample conditioning and recovery time\u003c\/li\u003e\n\u003cli\u003eImprove repeatability at low analyte concentrations\u003c\/li\u003e\n\u003cli\u003eMinimise surface interaction with H₂S, mercaptans and other sulfur compounds\u003c\/li\u003e\n\u003cli\u003eMaintain the mechanical strength and pressure capability of the stainless-steel housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe result is a filter housing particularly suited to analytical systems where \u003cstrong\u003esample integrity, response time and measurement repeatability\u003c\/strong\u003e are important.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eThe Model 122 SilcoNert® 2000 is particularly suited to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNatural gas analysis\u003c\/li\u003e\n\u003cli\u003eH₂S measurement\u003c\/li\u003e\n\u003cli\u003eSulfur analysis\u003c\/li\u003e\n\u003cli\u003eMercaptan analysis\u003c\/li\u003e\n\u003cli\u003eTrace gas analysis\u003c\/li\u003e\n\u003cli\u003eGas chromatograph sample systems\u003c\/li\u003e\n\u003cli\u003eRefinery analyser systems\u003c\/li\u003e\n\u003cli\u003ePetrochemical sample conditioning\u003c\/li\u003e\n\u003cli\u003eProcess gas analysers\u003c\/li\u003e\n\u003cli\u003eContinuous emissions monitoring\u003c\/li\u003e\n\u003cli\u003eLaboratory analytical systems\u003c\/li\u003e\n\u003cli\u003eHigh-pressure analytical sample systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFilter Housing Design\u003c\/h3\u003e\n\u003cp\u003eThe Model 122 is a compact \u003cstrong\u003e316L stainless steel filter housing\u003c\/strong\u003e designed for gaseous and liquid process streams.\u003c\/p\u003e\n\u003cp\u003eIts three-port configuration allows the housing to be used in a variety of analyser and sample conditioning arrangements, including \u003cstrong\u003ecoalescing filtration and bypass\/return configurations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe low internal volume helps minimise unnecessary sample volume within the conditioning system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFilter Element Options\u003c\/h3\u003e\n\u003cp\u003eThe Model 122 accepts Headline Filters \u003cstrong\u003e12-57 series filter elements\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eA range of filtration media is available depending on the application, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisposable bonded microfiber filter elements\u003c\/li\u003e\n\u003cli\u003eStainless steel filter elements\u003c\/li\u003e\n\u003cli\u003ePTFE filter elements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDifferent micron ratings and coalescing grades are available.\u003c\/p\u003e\n\u003cp\u003eIf you are unsure which element type or filtration grade is best suited to your analyser system, please contact Headline Filters for technical guidance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e 122 SilcoNert® 2000\u003cbr\u003e\u003cstrong\u003eHousing Material:\u003c\/strong\u003e 316L Stainless Steel\u003cbr\u003e\u003cstrong\u003eInternal Components:\u003c\/strong\u003e 316L Stainless Steel\u003cbr\u003e\u003cstrong\u003eSurface Treatment:\u003c\/strong\u003e SilcoNert® 2000\u003cbr\u003e\u003cstrong\u003eCoating Provider:\u003c\/strong\u003e SilcoTek® Corporation, USA\u003cbr\u003e\u003cstrong\u003ePort Size:\u003c\/strong\u003e 1\/4\" NPT\u003cbr\u003e\u003cstrong\u003eDrain Connection:\u003c\/strong\u003e 1\/4\" NPT\u003cbr\u003e\u003cstrong\u003eMaximum Working Pressure:\u003c\/strong\u003e 340 bar\u003cbr\u003e\u003cstrong\u003eMaximum Temperature:\u003c\/strong\u003e 200°C\u003cbr\u003e\u003cstrong\u003eInternal Volume:\u003c\/strong\u003e 30 cc\u003cbr\u003e\u003cstrong\u003eStandard Seal:\u003c\/strong\u003e Viton®\u003cbr\u003e\u003cstrong\u003eApproximate Housing Weight:\u003c\/strong\u003e 400 g\u003cbr\u003e\u003cstrong\u003eApproximate Packed Weight:\u003c\/strong\u003e 500 g\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eSeal Options\u003c\/h3\u003e\n\u003cp\u003eThe Model 122 is supplied with a \u003cstrong\u003eViton® O-ring as standard\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAlternative seal materials include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKalrez®\u003c\/li\u003e\n\u003cli\u003eSilicone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePlease contact us if you require an alternative sealing material for your application.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eImportant Information\u003c\/h3\u003e\n\u003cp\u003eSilcoNert® 2000 treatment improves the surface characteristics of the stainless-steel wetted components but \u003cstrong\u003edoes not increase the pressure or temperature rating of the Model 122 housing\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWhere very low-level or reactive compounds are being measured, the complete wetted sample path should be considered when specifying inert surface treatment.\u003c\/p\u003e\n\u003cp\u003eFor advice on filtration media, seal materials or suitability for a particular analyser application, please contact the Headline Filters technical team.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSilcoNert® and SilcoTek® are registered trademarks of SilcoTek Corporation.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Headline Filters","offers":[{"title":"Default Title","offer_id":56134119653761,"sku":"11220010SN2","price":4104.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/69FB4551-880D-4A71-A33E-97F3ED44F909.jpg?v=1787145858","url":"https:\/\/china.headlinefilters.com\/products\/model-122-silconert-2000","provider":"Headline Filters","version":"1.0","type":"link"}