{"title":"Membrane Separators","description":"\u003cp\u003eAnalyser Protection\u003c\/p\u003e","products":[{"product_id":"membrane-kit-mt-33-m4h-for-gms105","title":"Membrane Kit MT-33-M2H (for GMS105)","description":"\u003cp\u003e\u003cstrong\u003eKit contains:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x High Flow MT-33-M2H membrane with a bonded Viton O-Ring (for GMS105)\u003c\/li\u003e\n\u003cli\u003e1x Stainless Steel Sintered Disc\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable id=\"tablepress-62\" class=\"tablepress tablepress-id-62 tablepress-responsive\" style=\"width: 100%; height: 156.75px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"row-10 even\" style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"column-1\" style=\"width: 69.0519%; height: 19.5938px;\"\u003e\u003cstrong\u003eMembrane Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-3\" style=\"width: 30.5903%; height: 19.5938px;\"\u003e\u003cstrong\u003eMT.33.M2HG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-11 odd\" style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"column-1\" style=\"width: 69.0519%; height: 19.5938px;\"\u003eMembrane Type\u003c\/td\u003e\n\u003ctd class=\"column-3\" style=\"width: 30.5903%; height: 19.5938px;\"\u003eHigh Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-12 even\" style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"column-1\" style=\"width: 69.0519%; height: 19.5938px;\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"column-3\" style=\"width: 30.5903%; height: 19.5938px;\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-13 odd\" style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"column-1\" style=\"width: 69.0519%; height: 19.5938px;\"\u003eDiameter (mm)\u003c\/td\u003e\n\u003ctd class=\"column-3\" style=\"width: 30.5903%; height: 19.5938px;\"\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-14 even\" style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"column-1\" style=\"width: 69.0519%; height: 19.5938px;\"\u003e\u003cspan\u003eThickness (μm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"column-3\" style=\"width: 30.5903%; height: 19.5938px;\"\u003e152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-15 odd\" style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"column-1\" style=\"width: 69.0519%; height: 19.5938px;\"\u003eMaximum Temperature ºC (ºF)\u003c\/td\u003e\n\u003ctd class=\"column-3\" style=\"width: 30.5903%; height: 19.5938px;\"\u003e148 (300)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-16 even\" style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"column-1\" style=\"width: 69.0519%; height: 19.5938px;\"\u003eRecommended Flow Rate (LPM)\u003c\/td\u003e\n\u003ctd class=\"column-3\" style=\"width: 30.5903%; height: 19.5938px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-17 odd\" style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"column-1\" style=\"width: 69.0519%; height: 19.5938px;\"\u003eMembrane Micron Size\u003c\/td\u003e\n\u003ctd class=\"column-3\" style=\"width: 30.5903%; height: 19.5938px;\"\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Headline Filters","offers":[{"title":"Default Title","offer_id":44094781292738,"sku":"36000315","price":36.3,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/image_37ed68af-1710-4ae4-aaaf-4a6b79840ba9.jpg?v=1723631460"},{"product_id":"mounting-bracket-mb-gms105","title":"Mounting Bracket MB-GMS105","description":"\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eThis mounting bracket contains:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003c\/span\u003e1 x Stainless Steel Mounting Bracket\u003c\/p\u003e\n\u003cp\u003e2 x Stainless Steel Mounting Screws\u003c\/p\u003e\n\u003cp\u003e2 x  Stainless Steel Flat Washers\u003c\/p\u003e","brand":"Headline Filters","offers":[{"title":"Default Title","offer_id":44094808752322,"sku":"50030100","price":12.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/image_48c8329d-0f62-461e-b3b4-73209cdbf7f3.jpg?v=1723631294"},{"product_id":"model-gms100","title":"Membrane Filter Housing - Model GMS100","description":"\u003cp\u003e\u003cstrong\u003eThe Headline Guardian Membrane Separator filter consists of a highly porous PTFE membrane in a stainless steel or PTFE housing with two bypass ports, inlet and outlet ports.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ports and mounting bracket are designed to allow for permanent pipework, thereby enabling easy maintenance or replacement of the filter membrane. Within the housing 3 angled venturies cause the gas to be rotated beneath the membrane, helping to keep the membrane clean and at the same time allowing the finer gas molecules to pass through the membrane for gas sampling and leaving the larger liquid molecules to exit through the bypass ports. Further benefits of the Headline Membrane Filter are that it is extremely inert and is recommended for most applications, the only exception being hydrofluoric acid. It is always recommended to use a coalescing pre-filter and to use the membrane filter as the last form of protection. The membrane is currently available in high flow applications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eEach assembly is supplied with a Hydrophobic\/Oleophobic Membrane bonded to a Viton O-ring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe porous membranes are produced from pure PTFE; they are extremely inert and have very low absorption levels. There are two standard grades available for use in low to high flow applications. The M1H (0.1 micron) is a low flow type membrane suitable for most liquids and the M2H (0.8 micron) is a high flow type recommended for higher surface tension liquids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003ePTFE Membrane Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"tablepress tablepress-id-62 tablepress-responsive\" id=\"tablepress-62\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eMembrane Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u003cstrong\u003eMT.33.M1H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\u003cstrong\u003eMT.33.M2H\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-11 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Type\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eLow Flow\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003eHigh Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-12 even\"\u003e\n\u003ctd class=\"column-1\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003ePTFE\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-13 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eDiameter (mm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e33\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-14 even\"\u003e\n\u003ctd class=\"column-1\"\u003eThickness (μm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e152\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-15 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMaximum Temperature (ºC)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e150\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-16 even\"\u003e\n\u003ctd class=\"column-1\"\u003eRecommended Flow Rate (LPM)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.35\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-17 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Micron Size\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.1\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eMore about Guardian Membrane Separator Housings:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMany sample systems require zero liquid entrainment, and demand the sample not to be altered. At the heart of our Guardian Membrane Series is a porous PTFE Hydrophobic\/Oleophobic membrane which is supported by a stainless steel disc.  As a wet sample enters, the membrane only allows gas or vapor molecules to pass through while all liquids are stopped.  Our series of membrane filters are uniquely designed to allow the operator quick and easy membrane service while providing high performance filtration. The body contains an integral mounting bracket along with the inlet, outlet, drain, and bypass connections. The threaded cap is user friendly with knurls and flats for optimum infield serviceability.  No connections are broken to service the membrane disc.  Our GMS105 products also features an “Atomizer Plate” which spins the gas flow dropping much of the liquid mass out before contact is even made with the membrane.  This rotation assists in keeping the membrane particle free too.  We have further reduced the internal volume to minimize the sample lag time.\u003c\/p\u003e","brand":"Headline Filters","offers":[{"title":"1\/4\" NPT \/ M2- High Flow \/ 100°C - 100 bar","offer_id":44174658764994,"sku":"29200025","price":260.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/Photoroom-20241116_085852.png?v=1731747578"},{"product_id":"model-gms105","title":"Membrane Filter Housing - Model GMS105-1\/4\" NPT","description":"\u003cp\u003e\u003cstrong\u003eThe Headline Guardian Membrane Separator filter consists of a highly porous PTFE membrane in a stainless steel or PTFE housing with two bypass ports, inlet and outlet ports.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ports and mounting bracket are designed to allow for permanent pipework, thereby enabling easy maintenance or replacement of the filter membrane. Within the housing 3 angled venturies cause the gas to be rotated beneath the membrane, helping to keep the membrane clean and at the same time allowing the finer gas molecules to pass through the membrane for gas sampling and leaving the larger liquid molecules to exit through the bypass ports. Further benefits of the Headline Membrane Filter are that it is extremely inert and is recommended for most applications, the only exception being hydrofluoric acid. It is always recommended to use a coalescing pre-filter and to use the membrane filter as the last form of protection. The membrane is currently available in high flow applications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eEach assembly is supplied with a Hydrophobic\/Oleophobic Membrane bonded to a Viton O-ring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe porous membranes are produced from pure PTFE; they are extremely inert and have very low absorption levels. There are two standard grades available for use in low to high flow applications. The M1H (0.1 micron) is a low flow type membrane suitable for most liquids and the M2H (0.8 micron) is a high flow type recommended for higher surface tension liquids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003ePTFE Membrane Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable id=\"tablepress-62\" class=\"tablepress tablepress-id-62 tablepress-responsive\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eMembrane Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u003cstrong\u003eMT.33.M1H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\u003cstrong\u003eMT.33.M2H\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-11 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Type\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eLow Flow\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003eHigh Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-12 even\"\u003e\n\u003ctd class=\"column-1\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003ePTFE\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-13 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eDiameter (mm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e33\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-14 even\"\u003e\n\u003ctd class=\"column-1\"\u003eThickness (μm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e152\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-15 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMaximum Temperature (ºC)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e150\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-16 even\"\u003e\n\u003ctd class=\"column-1\"\u003eRecommended Flow Rate (LPM)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.35\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-17 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Micron Size\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.1\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eMore about Guardian Membrane Separator Housings:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMany sample systems require zero liquid entrainment, and demand the sample not to be altered. At the heart of our Guardian Membrane Series is a porous PTFE Hydrophobic\/Oleophobic membrane which is supported by a stainless steel disc.  As a wet sample enters, the membrane only allows gas or vapor molecules to pass through while all liquids are stopped.  Our series of membrane filters are uniquely designed to allow the operator quick and easy membrane service while providing high performance filtration. The body contains an integral mounting bracket along with the inlet, outlet, drain, and bypass connections. The threaded cap is user friendly with knurls and flats for optimum infield serviceability.  No connections are broken to service the membrane disc.  Our GMS105 products also features an “Atomizer Plate” which spins the gas flow dropping much of the liquid mass out before contact is even made with the membrane.  This rotation assists in keeping the membrane particle free too.  We have further reduced the internal volume to minimize the sample lag time.\u003c\/p\u003e","brand":"Headline Filters","offers":[{"title":"1\/4\" NPT \/ M2- High Flow \/ 100°C - 100 bar","offer_id":44174658797762,"sku":"29200030","price":414.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/Photoroom-20241115_213224.png?v=1731706364"},{"product_id":"model-gms170","title":"Membrane Filter Housing - Model GMS170","description":"\u003cp\u003e\u003cstrong\u003eThe Headline Guardian Membrane Separator filter consists of a highly porous PTFE membrane in a stainless steel or PTFE housing with two bypass ports, inlet and outlet ports.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis GMS170 filter has an integrated grade 50CS coalescing pre-filter fitted before the membrane. This intelligent design removes most solids \u0026amp; liquids before they reach the membrane, this helps to maximize the life span of the membrane. \u003c\/p\u003e\n\u003cp\u003eNot only that, it has a small internal volume for fast sample results and is mounted vertically (bowl up) or on it's side. This allows pipework to stay connected whilst servicing the internal components. \u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eEach assembly is supplied with a Hydrophobic\/Oleophobic Membrane bonded to a Viton O-ring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe porous membranes are produced from pure PTFE; they are extremely inert and have very low absorption levels. There are two standard grades available for use in low to high flow applications. The M1H (0.1 micron) is a low flow type membrane suitable for most liquids and the M2H (0.8 micron) is a high flow type recommended for higher surface tension liquids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003ePTFE Membrane Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"tablepress tablepress-id-62 tablepress-responsive\" id=\"tablepress-62\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eMembrane Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u003cstrong\u003eMT.33.M1H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\u003cstrong\u003eMT.33.M2H\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-11 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Type\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eLow Flow\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003eHigh Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-12 even\"\u003e\n\u003ctd class=\"column-1\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003ePTFE\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-13 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eDiameter (mm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e33\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-14 even\"\u003e\n\u003ctd class=\"column-1\"\u003eThickness (μm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e152\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-15 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMaximum Temperature (ºC)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e150\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-16 even\"\u003e\n\u003ctd class=\"column-1\"\u003eRecommended Flow Rate (LPM)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.35\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-17 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Micron Size\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.1\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eMore about Guardian Membrane Separator Housings:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMany sample systems require zero liquid entrainment, and demand the sample not to be altered. At the heart of our Guardian Membrane Series is a porous PTFE Hydrophobic\/Oleophobic membrane which is supported by a stainless steel disc.  As a wet sample enters, the membrane only allows gas or vapor molecules to pass through while all liquids are stopped.  Our series of membrane filters are uniquely designed to allow the operator quick and easy membrane service while providing high performance filtration. The body contains an integral mounting bracket along with the inlet, outlet, drain, and bypass connections. The threaded cap is user friendly with knurls and flats for optimum infield serviceability.  No connections are broken to service the membrane disc.  Our GMS105 products also features an “Atomizer Plate” which spins the gas flow dropping much of the liquid mass out before contact is even made with the membrane.  This rotation assists in keeping the membrane particle free too.  We have further reduced the internal volume to minimize the sample lag time.\u003c\/p\u003e","brand":"Headline Filters","offers":[{"title":"1\/4\" NPT \/ M2- High Flow \/ 100°C - 150 bar","offer_id":44174658928834,"sku":"29200035","price":297.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/Photoroom-20241115_213141.png?v=1731706337"},{"product_id":"model-gms122","title":"Membrane Filter Housing - Model GMS122","description":"\u003cp\u003e\u003cstrong\u003eThe Headline Guardian Membrane Separator filter consists of a highly porous PTFE membrane in a stainless steel or PTFE housing with two bypass ports, inlet and outlet ports.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ports and mounting bracket are designed to allow for permanent pipework, thereby enabling easy maintenance or replacement of the filter membrane. Within the housing 3 angled venturies cause the gas to be rotated beneath the membrane, helping to keep the membrane clean and at the same time allowing the finer gas molecules to pass through the membrane for gas sampling and leaving the larger liquid molecules to exit through the bypass ports. Further benefits of the Headline Membrane Filter are that it is extremely inert and is recommended for most applications, the only exception being hydrofluoric acid. It is always recommended to use a coalescing pre-filter and to use the membrane filter as the last form of protection. The membrane is currently available in high flow applications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eEach assembly is supplied with a Hydrophobic\/Oleophobic Membrane bonded to a Viton O-ring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe porous membranes are produced from pure PTFE; they are extremely inert and have very low absorption levels. There are two standard grades available for use in low to high flow applications. The M1H (0.1 micron) is a low flow type membrane suitable for most liquids and the M2H (0.8 micron) is a high flow type recommended for higher surface tension liquids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003ePTFE Membrane Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"tablepress tablepress-id-62 tablepress-responsive\" id=\"tablepress-62\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eMembrane Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u003cstrong\u003eMT.33.M1H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\u003cstrong\u003eMT.33.M2H\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-11 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Type\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eLow Flow\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003eHigh Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-12 even\"\u003e\n\u003ctd class=\"column-1\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003ePTFE\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-13 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eDiameter (mm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e33\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-14 even\"\u003e\n\u003ctd class=\"column-1\"\u003eThickness (μm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e152\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-15 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMaximum Temperature (ºC)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e150\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-16 even\"\u003e\n\u003ctd class=\"column-1\"\u003eRecommended Flow Rate (LPM)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.35\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-17 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Micron Size\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.1\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eMore about Guardian Membrane Separator Housings:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMany sample systems require zero liquid entrainment, and demand the sample not to be altered. At the heart of our Guardian Membrane Series is a porous PTFE Hydrophobic\/Oleophobic membrane which is supported by a stainless steel disc.  As a wet sample enters, the membrane only allows gas or vapor molecules to pass through while all liquids are stopped.  Our series of membrane filters are uniquely designed to allow the operator quick and easy membrane service while providing high performance filtration. The body contains an integral mounting bracket along with the inlet, outlet, drain, and bypass connections. The threaded cap is user friendly with knurls and flats for optimum infield serviceability.  No connections are broken to service the membrane disc.  Our GMS105 products also features an “Atomizer Plate” which spins the gas flow dropping much of the liquid mass out before contact is even made with the membrane.  This rotation assists in keeping the membrane particle free too.  We have further reduced the internal volume to minimize the sample lag time.\u003c\/p\u003e","brand":"Headline Filters","offers":[{"title":"1\/4\" NPT \/ M2- High Flow \/ 100°C - 100 bar","offer_id":44174658994370,"sku":"29200040","price":311.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/Photoroom-20241116_085821.png?v=1731747527"},{"product_id":"model-gms205","title":"Membrane Filter Housing - Model GMS205","description":"\u003cp\u003e\u003cstrong\u003eThe Headline Guardian Membrane Separator filter consists of a highly porous PTFE membrane in a stainless steel or PTFE housing with two bypass ports, inlet and outlet ports.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ports and mounting bracket are designed to allow for permanent pipework, thereby enabling easy maintenance or replacement of the filter membrane. Within the housing 3 angled venturies cause the gas to be rotated beneath the membrane, helping to keep the membrane clean and at the same time allowing the finer gas molecules to pass through the membrane for gas sampling and leaving the larger liquid molecules to exit through the bypass ports. Further benefits of the Headline Membrane Filter are that it is extremely inert and is recommended for most applications, the only exception being hydrofluoric acid. It is always recommended to use a coalescing pre-filter and to use the membrane filter as the last form of protection. The membrane is currently available in high flow applications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eEach assembly is supplied with a Hydrophobic\/Oleophobic Membrane bonded to a Viton O-ring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe porous membranes are produced from pure PTFE; they are extremely inert and have very low absorption levels. There are two standard grades available for use in low to high flow applications. The M1H (0.1 micron) is a low flow type membrane suitable for most liquids and the M2H (0.8 micron) is a high flow type recommended for higher surface tension liquids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003ePTFE Membrane Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable id=\"tablepress-62\" class=\"tablepress tablepress-id-62 tablepress-responsive\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eMembrane Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u003cstrong\u003eMT.61.M1H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\u003cstrong\u003eMT.33.M2H\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-11 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Type\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eLow Flow\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003eHigh Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-12 even\"\u003e\n\u003ctd class=\"column-1\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003ePTFE\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-13 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eDiameter (mm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e61\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-14 even\"\u003e\n\u003ctd class=\"column-1\"\u003eThickness (μm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e152\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-15 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMaximum Temperature (ºC)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e150\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-16 even\"\u003e\n\u003ctd class=\"column-1\"\u003eRecommended Flow Rate (LPM)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e2\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-17 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Micron Size\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.1\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eMore about Guardian Membrane Separator Housings:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMany sample systems require zero liquid entrainment, and demand the sample not to be altered. At the heart of our Guardian Membrane Series is a porous PTFE Hydrophobic\/Oleophobic membrane which is supported by a stainless steel disc.  As a wet sample enters, the membrane only allows gas or vapor molecules to pass through while all liquids are stopped.  Our series of membrane filters are uniquely designed to allow the operator quick and easy membrane service while providing high performance filtration. The body contains an integral mounting bracket along with the inlet, outlet, drain, and bypass connections. The threaded cap is user friendly with knurls and flats for optimum infield serviceability.  No connections are broken to service the membrane disc.  Our GMS105 products also features an “Atomizer Plate” which spins the gas flow dropping much of the liquid mass out before contact is even made with the membrane.  This rotation assists in keeping the membrane particle free too.  We have further reduced the internal volume to minimize the sample lag time.\u003c\/p\u003e","brand":"Headline Filters","offers":[{"title":"1\/4\" NPT \/ M2- High Flow \/ 100°C - 100 bar","offer_id":44174659223746,"sku":"29200060","price":545.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/Photoroom-20241115_215621.png?v=1731707809"},{"product_id":"model-gms105p","title":"Membrane Filter Housing - Model GMS105P","description":"\u003cp\u003e\u003cstrong\u003eThe Headline Guardian Membrane Separator filter consists of a highly porous PTFE membrane in a stainless steel or PTFE housing with two bypass ports, inlet and outlet ports.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eTHIS PRODUCT IS MADE FROM PTFE\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe ports and mounting bracket are designed to allow for permanent pipework, thereby enabling easy maintenance or replacement of the filter membrane. Within the housing 3 angled venturies cause the gas to be rotated beneath the membrane, helping to keep the membrane clean and at the same time allowing the finer gas molecules to pass through the membrane for gas sampling and leaving the larger liquid molecules to exit through the bypass ports. Further benefits of the Headline Membrane Filter are that it is extremely inert and is recommended for most applications, the only exception being hydrofluoric acid. It is always recommended to use a coalescing pre-filter and to use the membrane filter as the last form of protection. The membrane is currently available in high flow applications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eEach assembly is supplied with a Hydrophobic\/Oleophobic Membrane bonded to a Viton O-ring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe porous membranes are produced from pure PTFE; they are extremely inert and have very low absorption levels. There are two standard grades available for use in low to high flow applications. The M1H (0.1 micron) is a low flow type membrane suitable for most liquids and the M2H (0.8 micron) is a high flow type recommended for higher surface tension liquids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003ePTFE Membrane Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable id=\"tablepress-62\" class=\"tablepress tablepress-id-62 tablepress-responsive\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eMembrane Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u003cstrong\u003eMT.33.M1H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\u003cstrong\u003eMT.33.M2H\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-11 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Type\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eLow Flow\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003eHigh Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-12 even\"\u003e\n\u003ctd class=\"column-1\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003ePTFE\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-13 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eDiameter (mm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e33\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-14 even\"\u003e\n\u003ctd class=\"column-1\"\u003eThickness (μm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e152\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-15 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMaximum Temperature (ºC)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e150\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-16 even\"\u003e\n\u003ctd class=\"column-1\"\u003eRecommended Flow Rate (LPM)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.35\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-17 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Micron Size\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.1\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eMore about Guardian Membrane Separator Housings:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMany sample systems require zero liquid entrainment, and demand the sample not to be altered. At the heart of our Guardian Membrane Series is a porous PTFE Hydrophobic\/Oleophobic membrane which is supported by a stainless steel disc.  As a wet sample enters, the membrane only allows gas or vapor molecules to pass through while all liquids are stopped.  Our series of membrane filters are uniquely designed to allow the operator quick and easy membrane service while providing high performance filtration. The body contains an integral mounting bracket along with the inlet, outlet, drain, and bypass connections. The threaded cap is user friendly with knurls and flats for optimum infield serviceability.  No connections are broken to service the membrane disc.  Our GMS105 products also features an “Atomizer Plate” which spins the gas flow dropping much of the liquid mass out before contact is even made with the membrane.  This rotation assists in keeping the membrane particle free too.  We have further reduced the internal volume to minimize the sample lag time.\u003c\/p\u003e","brand":"Headline Filters","offers":[{"title":"1\/4\" NPT \/ M2- High Flow \/ 100°C - 7 bar","offer_id":44174659092674,"sku":"29200046","price":466.9,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/Photoroom-20241116_082429.png?v=1731745496"},{"product_id":"model-gms205p","title":"Membrane Filter Housing - Model GMS205P","description":"\u003cp\u003e\u003cstrong\u003eThe Headline Guardian Membrane Separator filter consists of a highly porous PTFE membrane in a stainless steel or PTFE housing with two bypass ports, inlet and outlet ports.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eTHIS PRODUCT IS MADE FROM PTFE\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ports and mounting bracket are designed to allow for permanent pipework, thereby enabling easy maintenance or replacement of the filter membrane. Within the housing 3 angled venturies cause the gas to be rotated beneath the membrane, helping to keep the membrane clean and at the same time allowing the finer gas molecules to pass through the membrane for gas sampling and leaving the larger liquid molecules to exit through the bypass ports. Further benefits of the Headline Membrane Filter are that it is extremely inert and is recommended for most applications, the only exception being hydrofluoric acid. It is always recommended to use a coalescing pre-filter and to use the membrane filter as the last form of protection. The membrane is currently available in high flow applications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eEach assembly is supplied with a Hydrophobic\/Oleophobic Membrane bonded to a Viton O-ring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe porous membranes are produced from pure PTFE; they are extremely inert and have very low absorption levels. There are two standard grades available for use in low to high flow applications. The M1H (0.1 micron) is a low flow type membrane suitable for most liquids and the M2H (0.8 micron) is a high flow type recommended for higher surface tension liquids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003ePTFE Membrane Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"tablepress tablepress-id-62 tablepress-responsive\" id=\"tablepress-62\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eMembrane Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u003cstrong\u003eMT.61.M1H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\u003cstrong\u003eMT.33.M2H\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-11 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Type\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eLow Flow\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003eHigh Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-12 even\"\u003e\n\u003ctd class=\"column-1\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003ePTFE\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-13 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eDiameter (mm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e61\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-14 even\"\u003e\n\u003ctd class=\"column-1\"\u003eThickness (μm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e152\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-15 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMaximum Temperature (ºC)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e150\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-16 even\"\u003e\n\u003ctd class=\"column-1\"\u003eRecommended Flow Rate (LPM)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e2\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-17 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Micron Size\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.1\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eMore about Guardian Membrane Separator Housings:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMany sample systems require zero liquid entrainment, and demand the sample not to be altered. At the heart of our Guardian Membrane Series is a porous PTFE Hydrophobic\/Oleophobic membrane which is supported by a stainless steel disc.  As a wet sample enters, the membrane only allows gas or vapor molecules to pass through while all liquids are stopped.  Our series of membrane filters are uniquely designed to allow the operator quick and easy membrane service while providing high performance filtration. The body contains an integral mounting bracket along with the inlet, outlet, drain, and bypass connections. The threaded cap is user friendly with knurls and flats for optimum infield serviceability.  No connections are broken to service the membrane disc.  Our GMS105 products also features an “Atomizer Plate” which spins the gas flow dropping much of the liquid mass out before contact is even made with the membrane.  This rotation assists in keeping the membrane particle free too.  We have further reduced the internal volume to minimize the sample lag time.\u003c\/p\u003e","brand":"Headline Filters","offers":[{"title":"1\/4\" NPT \/ M2- High Flow \/ 100°C - 7 bar","offer_id":44174659289282,"sku":"29200061","price":598.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/Photoroom-20241116_082502.png?v=1731745530"},{"product_id":"membrane-filter-housing-model-gms130","title":"Membrane Filter Housing - Model GMS130","description":"\u003cp\u003e\u003cstrong\u003eThe Headline Guardian Membrane Separator filter consists of a highly porous PTFE membrane in a stainless steel or PTFE housing with two bypass ports, inlet and outlet ports.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ports and mounting bracket are designed to allow for permanent pipework, thereby enabling easy maintenance or replacement of the filter membrane. Within the housing 3 angled venturies cause the gas to be rotated beneath the membrane, helping to keep the membrane clean and at the same time allowing the finer gas molecules to pass through the membrane for gas sampling and leaving the larger liquid molecules to exit through the bypass ports. Further benefits of the Headline Membrane Filter are that it is extremely inert and is recommended for most applications, the only exception being hydrofluoric acid. It is always recommended to use a coalescing pre-filter and to use the membrane filter as the last form of protection. The membrane is currently available in high flow applications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eEach assembly is supplied with a Hydrophobic\/Oleophobic Membrane bonded to a Viton O-ring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe porous membranes are produced from pure PTFE; they are extremely inert and have very low absorption levels. There are two standard grades available for use in low to high flow applications. The M1H (0.1 micron) is a low flow type membrane suitable for most liquids and the M2H (0.8 micron) is a high flow type recommended for higher surface tension liquids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003ePTFE Membrane Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"tablepress tablepress-id-62 tablepress-responsive\" id=\"tablepress-62\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eMembrane Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u003cstrong\u003eMT.33.M1H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\u003cstrong\u003eMT.33.M2H\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-11 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Type\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eLow Flow\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003eHigh Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-12 even\"\u003e\n\u003ctd class=\"column-1\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003ePTFE\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-13 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eDiameter (mm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e33\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-14 even\"\u003e\n\u003ctd class=\"column-1\"\u003eThickness (μm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e152\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-15 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMaximum Temperature (ºC)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e150\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-16 even\"\u003e\n\u003ctd class=\"column-1\"\u003eRecommended Flow Rate (LPM)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.35\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-17 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Micron Size\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.1\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eMore about Guardian Membrane Separator Housings:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMany sample systems require zero liquid entrainment, and demand the sample not to be altered. At the heart of our Guardian Membrane Series is a porous PTFE Hydrophobic\/Oleophobic membrane which is supported by a stainless steel disc.  As a wet sample enters, the membrane only allows gas or vapor molecules to pass through while all liquids are stopped.  Our series of membrane filters are uniquely designed to allow the operator quick and easy membrane service while providing high performance filtration. The body contains an integral mounting bracket along with the inlet, outlet, drain, and bypass connections. The threaded cap is user friendly with knurls and flats for optimum infield serviceability.  No connections are broken to service the membrane disc.  Our GMS105 products also features an “Atomizer Plate” which spins the gas flow dropping much of the liquid mass out before contact is even made with the membrane.  This rotation assists in keeping the membrane particle free too.  We have further reduced the internal volume to minimize the sample lag time.\u003c\/p\u003e","brand":"Headline Filters","offers":[{"title":"1\/4\" NPT \/ M2- High Flow \/ 100°C - 100 bar","offer_id":44586315743426,"sku":"29200083","price":545.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/Photoroom-20241118_110040.png?v=1731927664"},{"product_id":"membrane-kit-mt61-m3-to-fit-gms205","title":"Membrane Kit MT61.M3 (To fit GMS205)","description":"\u003cp\u003eThis Kit contains:\u003c\/p\u003e\n\u003cp\u003e1 x MT61.M3 Membrane\u003c\/p\u003e\n\u003cp\u003e2 x O-rings\u003c\/p\u003e\n\u003c!----\u003e","brand":"Headline Filters","offers":[{"title":"Default Title","offer_id":44622320468162,"sku":"36000316","price":72.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/Photoroom-20241118_110125.png?v=1731927711"},{"product_id":"membrane-kit-for-filter-housing-model-gms170-contains-filter-element-22-34-27-50cs","title":"Membrane Kit for Filter Housing Model GMS170 (contains filter element 22\/34-27-50CS) - MKGMS170","description":"\u003cp\u003eThis membrane kit contains everything you need to service our filter housing model GMS170. \u003c\/p\u003e\n\u003cp\u003eWithin the kit you will find the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3 x stainless steel grub screws\u003c\/li\u003e\n\u003cli\u003e1 x Allen Key \u003c\/li\u003e\n\u003cli\u003e1 x Viton O-ring for the head to bowl connection\u003c\/li\u003e\n\u003cli\u003e1 x Viton O-ring for the Element Support\u003c\/li\u003e\n\u003cli\u003e1 x Filter Element 22\/34-27-50CS\u003c\/li\u003e\n\u003cli\u003e1 x MT.33.M2H Membrane with bonded Viton O-ring\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Headline Filters","offers":[{"title":"Default Title","offer_id":44733270917314,"sku":"36000300","price":35.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/Photoroom-20241115_212717.png?v=1731706073"},{"product_id":"mounting-bracket-mb-gms170-copy","title":"Mounting Bracket MB-GMS170","description":"\u003cp\u003eThis kits consists of:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1 x Stainless Steel Mounting Bracket\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2 x Stainless Steel Washers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2 x Stainless Steel Hex Screws\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis mounting bracket will fit the following filter housings:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFilter Model GMS170\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Headline Filters","offers":[{"title":"Default Title","offer_id":44740903993538,"sku":"50030101","price":16.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/Photoroom-20241001_131708.png?v=1727785104"},{"product_id":"membrane-kit-mt61-m2h-to-fit-gms205","title":"Membrane Kit MT61.M2H (To fit GMS205)","description":"\u003cp\u003eThis Kit contains:\u003c\/p\u003e\n\u003cp\u003e1 x MT61.M2H Membrane\u003c\/p\u003e\n\u003cp\u003e2 x O-rings\u003c\/p\u003e\n\u003c!----\u003e","brand":"Headline Filters","offers":[{"title":"Default Title","offer_id":55188490224001,"sku":"36000311","price":72.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/Photoroom-20241118_110125.png?v=1731927711"},{"product_id":"membrane-filter-housing-model-gms105-1-8-npt","title":"Membrane Filter Housing - Model GMS105-1\/8\" - MT33-M1","description":"\u003cp\u003e\u003cstrong\u003eThe Headline Guardian Membrane Separator filter consists of a highly porous PTFE membrane in a stainless steel or PTFE housing with two bypass ports, inlet and outlet ports.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ports and mounting bracket are designed to allow for permanent pipework, thereby enabling easy maintenance or replacement of the filter membrane. Within the housing 3 angled venturies cause the gas to be rotated beneath the membrane, helping to keep the membrane clean and at the same time allowing the finer gas molecules to pass through the membrane for gas sampling and leaving the larger liquid molecules to exit through the bypass ports. Further benefits of the Headline Membrane Filter are that it is extremely inert and is recommended for most applications, the only exception being hydrofluoric acid. It is always recommended to use a coalescing pre-filter and to use the membrane filter as the last form of protection. The membrane is currently available in high flow applications.\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eEach assembly is supplied with a Hydrophobic\/Oleophobic Membrane bonded to a Viton O-ring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe porous membranes are produced from pure PTFE; they are extremely inert and have very low absorption levels. There are two standard grades available for use in low to high flow applications. The M1H (0.1 micron) is a low flow type membrane suitable for most liquids and the M2H (0.8 micron) is a high flow type recommended for higher surface tension liquids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003ePTFE Membrane Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable id=\"tablepress-62\" class=\"tablepress tablepress-id-62 tablepress-responsive\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\u003cstrong\u003eMembrane Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\u003cstrong\u003eMT.33.M1H\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\u003cstrong\u003eMT.33.M2H\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-11 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Type\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eLow Flow\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003eHigh Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-12 even\"\u003e\n\u003ctd class=\"column-1\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003ePTFE\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-13 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eDiameter (mm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e33\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-14 even\"\u003e\n\u003ctd class=\"column-1\"\u003eThickness (μm)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e152\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-15 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMaximum Temperature (ºC)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e150\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-16 even\"\u003e\n\u003ctd class=\"column-1\"\u003eRecommended Flow Rate (LPM)\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.35\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-17 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eMembrane Micron Size\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e0.1\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eMore about Guardian Membrane Separator Housings:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMany sample systems require zero liquid entrainment, and demand the sample not to be altered. At the heart of our Guardian Membrane Series is a porous PTFE Hydrophobic\/Oleophobic membrane which is supported by a stainless steel disc.  As a wet sample enters, the membrane only allows gas or vapor molecules to pass through while all liquids are stopped.  Our series of membrane filters are uniquely designed to allow the operator quick and easy membrane service while providing high performance filtration. The body contains an integral mounting bracket along with the inlet, outlet, drain, and bypass connections. The threaded cap is user friendly with knurls and flats for optimum infield serviceability.  No connections are broken to service the membrane disc.  Our GMS105 products also features an “Atomizer Plate” which spins the gas flow dropping much of the liquid mass out before contact is even made with the membrane.  This rotation assists in keeping the membrane particle free too.  We have further reduced the internal volume to minimize the sample lag time.\u003c\/p\u003e","brand":"Headline Filters","offers":[{"title":"1\/8\" NPT \/ M1- Low Flow \/ 100°C - 100 bar","offer_id":55516550463873,"sku":"29200038","price":414.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0636\/7369\/6450\/files\/Photoroom-20241115_213224.png?v=1731706364"}],"url":"https:\/\/china.headlinefilters.com\/collections\/membrane-separators.oembed","provider":"Headline Filters","version":"1.0","type":"link"}